1-4 TimeVault™ User’s Manual 6000-100Ch1.fm Rev. D
Chapter 1: General Information Environmental Specifications
1.7 Environmental Specifications
The environmental specifications of TimeVault are:
Operating Temperature
TimeVault Module: 0 to +50 °C (+32 to +122 °F)
Antenna: –40 to +70 °C (–40 to +158° F)
Maximum Rate of Change: 8 °C per hour
Storage Temperature
TimeVault Module: –50 to +85 °C (–40 to +185 °F)
Antenna: –55 to +85 °C (–67 to +185 °F)
Maximum Rate of Change: 15 °C per hour
Operating Humidity
TimeVault Module: 0% up to 95%, non-condensing
Antenna: 100%, condensing
Storage Humidity
TimeVault Module: 0% up to 95%, non-condensing
Antenna: 100%, condensing
Operating Altitude
TimeVault Module: Maximum 4 km
Storage Altitude
TimeVault Module: Maximum 12 km
Shock & Vibration Requirements
In Shipping Container: Per ISTA Procedure 2A
Bench Handling without Shipping
Container:
Per EN60068-2-31